roof-construction-for-slurry-tank

Emissions roof for slurry tank

This reference shows the roof construction on top of an existing corrugated stainless steel tank. The roof construction is a membrane roof with fibre-reinforced PVC which is resistant to sun, wheather and manure. The construction is realised within one day. At first a crane is necessary to position the central support in the middle of the manure tank. The central support is made from steel and specially coated. Afterwards the construction of the membrane starts which is fixed with stainless steel brackets at the tank. Then the roof is straightened across the central support and results in a equal tension (biaxial). The incline of the roof is about 25° to guarantee an optimised flow of rain. The circumferential drip edge prevents from condensation water running off the tank wall. Moreover, the membrane roof has two operating holes as well as wall bushings for pipes. 

Watch the entire roof construction for the slurry tank in the time-lapse video on our Youtube Channel

Technical Data
Diameter: 14,165 m
Hight: 4,38 m
Volume: 690 m³
Location

Lower Saxony, Germany

Please contact us for any further information.

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies). You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.